Product Code | YJ69337 |
---|---|
Description | Leak detector - Accuprobe UV |
Unit | Each |
Notes | Use the electrolyte sensor or UV technology (or both at the same time) to detect HFC, HCFC and HFO refrigerants, including SNAP approved hydrocarbon blends. The Smart Alarm LED shows how big or small a leak is on a scale of one to nine. With the electrolyte sensor, UV lights and Smart Alarm indicator, this is the only tool you need for fast, easy and certain leak detection. Sensitivity: HFC 0.06 oz.(1.7 g)/year; HCFC 0.03 oz.(0.9 g)/year; HFO 0.15 oz. (4.3 g)/year. Heated solid electrolyte sensor: over 300 hours service life with minimal cleaning and no adjustments. Maintenance required: none Operating temperature range: 24° to 125°F (-4° to 52°C) Storage temperature range: -4° to 122°F (-20° to 50°C) Humidity: 0 to 95% RH non-condensing Power: 4 AA alkaline batteries, 4.5 hours continuous life Body length: 10.5" (270 mm) Probe length: 17" (430 mm) Weight: 17 oz. (480 g) Warm up time: 20 seconds or less Calibration: Automatic Response time: Instantaneous Approvals: SAE J2791 certified, CE marked, EN 14624 Spare parts available as below, sold separately Replacement sensor and filter part number - YJ69384 Replacement filters, 5 pack part number - YJ69385 |
Image | |
Web URL | http://yellowjacket.com/ |
Documents |